GETTING AND SETTING OIDS
EMM-E6 User’s Guide 9-5
4. Press the Return key. If there is no instance of that OID, the EMM-E6
displays “MIB_NO_INSTANCE.” Otherwise, the EMM-E6 displays
that OID’s data type, length, and value.
To get the next OID:
1. Highlight GETNEXT, using the arrow keys.
2. Press the Return key. “<GETNEXT> OID (=|F9)” appears.
3. Enter the OID.
4. Press the Return key. If that OID does not exist, the EMM-E6 displays
“MIB_NO_INSTANCE”. Otherwise the EMM-E6 displays that
OID’s data type, length, and value.
To set an OID:
1. Highlight SET, using the arrow keys.
2. Press the Return key. “<SET> OID (=|F9)” appears.
3. Enter an OID.
4. Press the Return key. If that OID does not exist, the EMM-E6 displays
“MIB_NO_INSTANCE”. Otherwise the EMM-E6 displays:
{INteger String Null OId IP address Counter Gauge Timeticks OPaque}
“DATA TYPE (name):”
If you have previously entered an OID, press F9 to recall that
entry. You can use the arrow keys to modify the recalled OID,
or if you have not previously entered the OID, type the OID
minus the OID’s prepend.
TIP